This diagram shows the preferred method of cross connection field wiring from your IDFs or zones while only utilizing 2 66 blocks pe
r
station card. Note that this configuration does not utilize bridging clips but offers the flexibility associated with cross connect.
Connectivity for a single station card is shown. In cases where IDFs will serve more than 12 points (zones), distribution cables and an
IDF 66 block will be required for each increment of 12 or less. Be certain to plan for adequate backboard space for system 66 blocks,
power supplies, attenuators (volume controls) and wall racks.