Revised May 15, 2006
Commonly overlooked when configuring Valcom MultiPath Systems
The MultiPath System Design Tool allows users to correctly configure the
Valcom manufactured equipment required for a MultiPath Intercom System. The
following is a partial list of miscellaneous items that may be required for your
installation.
alcom VM-150
66 Blocks
1
2 per V-TCM/V-STX/V-URI
1 per VCRCA/VCRRK/XP-TCM12
2
1 per V-CPU4
3 per VC-24
2 per VC-24EXP
As required for IDFs
25 pair cables with female Amphenol connectors
2 per V-TCM/V-STX/V-URI
1 per VCRCA/VCRRK/XP-TCM12
1 per V-CPU4
3 per VC-24
2 per VC-24EXP
¾” Plywood Backboards
3
Distribution Rings
Bridging Clips
19” Racks (for MDF and RIDFs if applicable)
Rack Blanks (various sizes)
Be certain to account for at least 1 rack unit
between each piece of equipment for ventilation.
Single gang electrical boxes for call switches
Microphone (if required)
XLR Connectors for microphones
Music Sources
RCA Connectors for Music Sources
Slave Relays for:
door unlocking
lighting control
other control functions
Appropriate Network Switches for VoIP interface
VLAN components for VCRCA connectivity
AC Power Strips
1:1 Transformers for Remote Amplifiers/Remote Aux Sources
External Antennas for Aux Source Radios
alcom XP-RFB
1
Retrofit applications using heavy gauge speaker wire will require either the
Valcom VM-150 Screw Terminal Connection Block or XP-RFB Retrofit Block for
head end speaker wire connections. Heavy gauge speaker wire does not punch
down on 66 blocks.
Page 15 of 36